Öffnungszeit

Mon - Fri, 8:00 - 9:00

WhatsApp

+8618037022596

Schreiben Sie uns eine E-Mail

[email protected]

AXCA Series ASCX Compatible Amplified Pressure Sensors ...

+

• Supply Voltage: + to + Vdc • Lead Soldering Temperature (24 sec.): 250 °C • Quiescent Current: mA • Compensated Temperature: 0 to 70°C • Operating Temperature: 25 to 105°C • Storage Temperature: 55 to 125°C • Humidity Limits (non condensing): 0 to 95% RH. Model Number: 15 PSIA4VASCX; Data Sheet: Quantity:+ Inquire Now Add to cart. Mouse over image to zoom ...

5 Gas Analyzer CO/CO2/HC/O2/NOx Bridge Analyzers

+

The Bridge Analyzer 5 Gas Analyzer measures Carbon Monoxide (CO), Carbon Dioxide (CO2), Fuel Dependent Hydro Carbons (HC), Oxygen (O2) and Nitric Oxide (NOx). The 5 Gas Analyzer comes in a hard case with all accessories as a complete, readytouse gas analyzer. Turn on the power switch, connect the hose and probe, push the Zero button. When the Zero is complete, the analyzer is ready …

Carbon Dioxide Transmitters | JLC International ...

+

Carbon Dioxide Range: 0 – 2000 ppm / 0 – 5000 ppm / 0 – 10000 ppm ; Accuracy: < ± (50 ppm + 2% of reading) 0 – 2000 ppm < ± (50 ppm + 3% of reading) 0 – 5000 ppm < ± (100 ppm + 5% of reading) 0 – 10000 ppm; Outputs: 0 – 5 V / 0 – 10 V / 4 – 20 mA; Supply voltage: 24 Vac ± 20% / 15 – 35 Vdc; Auto calibration / Longterm stability; High resistance to pollution; Enclosure ...

TWXP WIRELESS SINGLE GAS TRANSMITTER

+

CO2 (Dynament IR) <65mA <170mA SENSOR LIST T90 SECONDS OP. TEMP. OP REL. HUM. EXPECTED LIFE WARRANTY Combustible Catalytic 0 LEL in 1% increments <20 40 to 50C 0 to 90 NC 24 Months 12 Combustible Infrared 0 LEL in 1% increments <20 40 to 60C 0 to 98 NC 60 Months 12 PID ppm in ppm increments <2 40 to 60C 0 to 99 NC 60 Months 12 …

AP200: CO2/H2O Atmospheric Profile System

+

Overview. The AP200 is a complete, integrated CO 2 and H 2 O atmospheric profile system. It measures carbon dioxide (CO 2) and water vapor (H 2 O) concentration from up to eight intakes, which are normally spaced along the height of a tower to give a vertical profile. The AP200 is often used in conjunction with an eddycovariance system to measure the storage term and provide you with a more ...

HIGH RANGE CARBON DIOXIDE SENSOR Exd Certified versions ...

+

Range 2 0 volume carbon dioxide If the sensor requires either a “Zero” or “Span” adjustment, there are three methods that can be ... mA Current waveform for Premier low power sensor. 20mA Current peak 34 mA . TDS0148 Issue 21/1/20 Change 652 Page 7 of 11 Sensor fault indication The sensor constantly performs checks on the internal memory contents, the incoming supply ...

LGH240H4M, Gas/Electric, Packaged Rooftop Unit, High ...

+

Horsepower . Blower Type or Drive 7 . Econ./ Single Temp./ Baro. Relief Yes . MSAV Yes . Heat 480 Dual . IEER . Return Opening Horizontal 15 X . Return Opening Downflow 15 X . Supply Opening Horizontal 14 x 75 . Supply Opening Downflow 20 X 28 . Gross Weight 2525 LB. Family LGH . Cooling Capacity Ton Cooling . Heating Capacity 480, 000 Btuh . Efficiency EER ...

Mass Flow Meters | sensors and sensing equipment | Omega

+

FMA5000ASeries. The FMA5400A/5500A Series electronic gas mass flow controllers provide for controlling the flow of a wide variety of gases from 010 SCCM up to 100 SLM. View Full Specifications. Added to Your Shopping Cart. Mass Flow Controllers and Meters for All Clean Gases.

Digital Camera Sensor Sizes

+

The following is a list of all sensor sizes (actual sizes) with their corresponding dimensions: Note: Actual size is set to screen → change ». Actual sensor size. Diagonal. Surface Area. Aspect Ratio. 1/4" (~ x mm) mm. mm².

TRLPe100 TRLPe100C ERV INSTALLATION, OPERATION ...

+

trlpe100 trlpe100c erv installation, operation and maintenance manual 3 table of contents overview 5

Power Supplies Transformers | Veris

+

0 Item(s) Shop Products CO2 Sensors Temperature Sensors Pressure Sensors Humidity Sensors VOC Sensors Gas Detection Current Monitoring Flow BTU Meters Power Energy Monitoring Power Supplies Transformers Relays Network Communication Modules Setpoint Devices Smoke Detection Water Leak Detection Occupancy Sensors Resources Support. Software Downloads …

HIGH RANGE CARBON DIOXIDE SENSOR Exd Certified …

+

Range 2 0 volume carbon dioxide If the sensor requires either a “Zero” or “Span” adjustment, there are three methods that can be ... mA Current waveform for Premier low power sensor. 20mA Current peak 34 mA . TDS0148 Issue 21/1/20 Change 652 Page 7 of 11 Sensor fault indication The sensor constantly performs checks on the internal memory contents, the incoming supply ...

Product Overview˜ AutomatikCentret

+

air quality sensors order number air + rh t°c co 2 t°c, co2, rh lfh00˜2b65 lfh01˜2b65 lfh10˜2b65 lfh20˜2b65 aqs˜kam˜00 aqs˜kam˜01 aqs˜kam˜10 aqs˜kam˜20 aqs 71˜kam˜t aqs˜kam˜rh˜v

CO2 Pro .NET Framework

+

Sensor Performance Accuracy ±% Resolution ppm Zero drift automatic zero compensation Equilibration time (t 63) water: min air: 5 sec Standard ranges (alternate ranges available) 0 600 ppm 0 1000 ppm 0 2000 ppm Physical CO 2Pro™ Submersible: Length 33 cm (13 in) Diameter 19 cm ( in) Weight Air: kg ( lbs) Water: kg ( lbs) Housing Acetal Plastic Depth 5 m ...

Economizer Retrofi t Solutions

+

up to Tons LF24SR Tons NFB24SR 1215 Tons AFB24SR 1530 Tons ECONZIP BASE ECONZIP10K (Supply Air Sensor) AND OR ECONZIPTH ECONZIP10K DRY BULB ENTHALPY Note: Differential control requires one additional sensor for return air. • Demand Control Ventilation (DCV)* ECONZIPEM + CO2 sensor of your choice (02000PPM, 010VDC). • Preoccupancy …

August (issue 373) Circuit Cellar Circuit Cellar

+

20210719· Manufacturer or Brand: Sensor ID: Voltage Input (VDC) Peak Current (mA) Operating Temp. (°C) Comm. Protocol: CozIR: GC0012: – : 33: 0 – 50: UART: SenseAir

KH20: Krypton Hygrometer with Case Campbell Sci

+

Heat, Water Vapor, and CarbonDioxide Flux Sensors / KH20 ... 29 x 23 x 3 cm ( x 9 x in.) for sensor head; 19 x 13 x 5 cm ( x 5 x 2 in.) for electronics box; 29 x 18 x cm ( x 7 x in.) for rain shield with mount; 64 x 38 x 18 cm (25 x 15 x 7 in.) for carrying case ; Weight kg (15 lb) Compatibility. Please note: The following shows notable compatibility information ...

AirSense™ Model 400 OEM Infrared Carbon Dioxide Sensor

+

Measurement Range 020% CO 2 Repeatability ± .1% CO 2 Measurement Accuracy ± 5% of reading or .1% CO 2 (whichever is greater) Recommended Calibration Interval 5 years Warm Up Time Less than 1 minute Power Requirements 15 VDC 170 mA max (125 average) Approx. with 12V. input Power Consumption Less than 1 watt

PRESSURE SENSORS FOR LIQUIDS GASES

+

Level Sensor 02,5 PSI to 015 PSI vented gauge ±0,25% 420 mA [1028 VDC] 15 VDC, [1028 VDC] AST4530 Submersible Pressure Transducer PVDF/PTFE 02,5 PSI to 07,5 PSI vented gauge ±0,5% 420 mA [1028 VDC] 15 VDC, [1028 VDC] U5700 Submersible Pressure Transducer 00,35 mbar to 0700 bar vented gauge/ absolute ±0,1 % bis ±0,75 % 0,54,5 V ratiometr. [5 VDC] 420 mA [930 VDC] …

Greisinger Hauptkatalog 2015 Zubehör siehe seite ...

+

20150209· Kurzschlussfest: ja (passiv) Betriebstemperatur: 0 ... 50 °C Betriebstemperatur: 0 ... 50 °C Feuchte: 20 ... 80 % nicht betauend Feuchte: 20 ... 80 % nicht betauend Lagertemperatur: 20 ... +70 °C Lagertemperatur: 20 ...+70 °C Abmessungen (L x B x H): 112 x 80 x 45 mm Abmessungen (L x B x H): 100 x 75 x 110 mm BitRecovery nein BitRecovery ja Lieferumfang: Schnittstellen ...

en0b0457ge51r0514 Honeywell

+

Sensor life expectancy > 15 years, maintenancefree Protection class IP20 as per EN 60529 CO2 Measurement Range 0…2000 ppm or (jumper position “0”) 0…3000 ppm Output (pins 12) 0…10 Vdc for max. 2 mA Accuracy factorycalibration ±50 ppm or ±5% of measurement range Pressure dependence +% per kPa deviation from normal pressure of 100 kPa Response time 90% penetration within 1 …

Hinterlasse einen Kommentar